Summary0000272: lier des bornes
Descriptionsalut

quand tu mets des bornes est-il possible de lier des bornes sur un folios bornier

merci
TagsNo tags attached.

Activities

scorpio810_mantis

2022-09-08 09:02

administrator   ~0000581

Salut,
sois plus clair car je n'ai rien compris.

scorpio810_mantis

2022-09-08 11:42

administrator   ~0000582

https://qelectrotech.org/forum/viewtopic.php?id=1007

ispyisail

2026-09-24 11:24

developer   ~0000882

If you mean linking terminals together on a terminal strip: that is terminal bridges, added by commit ce8bd7f (December 2021) and in every release since QElectroTech 0.9. Open the terminal strip editor, select the terminals, and bridge them.
https://github.com/qelectrotech/qelectrotech-source-mirror/commit/ce8bd7fa

If you meant something else, add a note here and we will reopen this.