2019-09-20 20:03 CEST

View Issue Details Jump to Notes ]
IDProjectCategoryView StatusLast Update
0000146QElectroTechDiagram Editorpublic2018-03-29 16:19
Reporterbenio 
Assigned Toblack_sun 
PrioritynormalSeverityminorReproducibilityalways
StatusresolvedResolutionfixed 
PlatformWindowsOSWindows 7OS Version
Product Version 
Target VersionFixed in VersionSVN/trunk 
Summary0000146: NUMBERING CABLE AFTER NEX PAGE CONTINUE POTENTIAL
DescriptionIts bug.

I have numbering cable (folio:number) on page 1 - 1:1.

I move the potential to nex page 2 and draw conductor. New conductor have conductor numer 1:1 its ok.

But when i edit line on page 1 or 2 example add voltage automatically numbering on page 2 change to 2:1.


best regards.
TagsNo tags attached.
Attached Files

-Relationships
+Relationships

-Notes

~0000263

scorpio810 (administrator)

Hi,
numbering conductors to page/folio id isn't a good choice, but I think is already fixed
https://qelectrotech.org/forum/viewtopic.php?pid=6172#p6172

Best regards,
Laurent

~0000335

black_sun (developer)

Fix in r4845 aand r4848
+Notes

-Issue History
Date Modified Username Field Change
2017-11-16 14:45 benio New Issue
2017-11-16 18:19 scorpio810 Note Added: 0000263
2018-03-29 16:19 black_sun Assigned To => black_sun
2018-03-29 16:19 black_sun Status new => resolved
2018-03-29 16:19 black_sun Resolution open => fixed
2018-03-29 16:19 black_sun Fixed in Version => SVN/trunk
2018-03-29 16:19 black_sun Note Added: 0000335
+Issue History