View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000146 | QElectroTech | website | public | 2017-11-16 14:45 | 2021-02-15 00:50 |
Reporter | benio | Assigned To | black_sun | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Platform | Windows | OS | Windows 7 | ||
Summary | 0000146: NUMBERING CABLE AFTER NEX PAGE CONTINUE POTENTIAL | ||||
Description | Its bug. I have numbering cable (folio:number) on page 1 - 1:1. I move the potential to nex page 2 and draw conductor. New conductor have conductor numer 1:1 its ok. But when i edit line on page 1 or 2 example add voltage automatically numbering on page 2 change to 2:1. best regards. | ||||
Tags | No tags attached. | ||||
|
Hi, numbering conductors to page/folio id isn't a good choice, but I think is already fixed https://qelectrotech.org/forum/viewtopic.php?pid=6172#p6172 Best regards, Laurent |
|
Fix in r4845 aand r4848 |
Date Modified | Username | Field | Change |
---|---|---|---|
2017-11-16 14:45 | benio | New Issue | |
2017-11-16 18:19 | scorpio810_mantis | Note Added: 0000263 | |
2018-03-29 16:19 | black_sun | Assigned To | => black_sun |
2018-03-29 16:19 | black_sun | Status | new => resolved |
2018-03-29 16:19 | black_sun | Resolution | open => fixed |
2018-03-29 16:19 | black_sun | Fixed in Version | => SVN/trunk |
2018-03-29 16:19 | black_sun | Note Added: 0000335 | |
2021-02-15 00:47 |
|
Product Version | => SVN/trunk |
2021-02-15 00:50 |
|
Category | Diagram Editor => website |